112.5 kVA Transformers

A 112.5 kVA dry-type transformer is one of the most widely installed mid-range distribution units in North American electrical infrastructure used across commercial construction, industrial facilities, data centers, healthcare, and transportation projects throughout the U.S. All units in this category are three-phase, air-cooled, and available in a wide range of primary and secondary voltage configurations, enclosure types, and efficiency classes.

 

Bruce Electric Equipment has been supplying dry-type transformers across the U.S. since 1973. We stock new 112.5 kVA transformer units from leading manufacturers including Acme Electric and Hammond Power Solutions, covering the full range of standard voltage configurations, enclosure types, and efficiency classes. Used and reconditioned 112.5 kVA transformers are not listed online but are available upon request contact us for custom sourcing and RFQ support.

Showing 1–15 of 438 results

9T83B3837

SKU: 9T83B3837
Manufacturer: General Electric

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 600

SECONDARY VOLTAGE : 240

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 2

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 208V - 480Y/277V (SH3U0112BK2KG)

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 208V - 480Y/277V (SH3U0112BK2KG)

SKU: SH3U0112BK2KG
Manufacturer: Hammond Power Solutions
Weight: 1000 lbs

KVA : 112.5

PHASE : THREE

WINDING MATERIAL : COPPER

TRADE NAME IF ANY : HPS SUPERCENTURION

PRIMARY VOLTAGE : 208

SECONDARY VOLTAGE : 480Y/277

TYPE : simple

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 480V - 480Y/277V (SH3U0112KK2SG)

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 480V - 480Y/277V (SH3U0112KK2SG)

SKU: SH3U0112KK2SG
Manufacturer: Hammond Power Solutions
Weight: 960 lbs

KVA : 112.5

PHASE : THREE

WINDING MATERIAL : ALUMINUM

TRADE NAME IF ANY : HPS SUPERCENTURION

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 480Y/277

TYPE : simple

9T99C9805G03

SKU: 9T99C9805G03
Manufacturer: General Electric

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 208

SECONDARY VOLTAGE : 480Y/277

WINDING MATERIAL : COPPER

HZ : 60

ENCLOSURE : NEMA 3R

TYPE : HARMONIC MITIGATING GUARD 3

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 380

WINDING MATERIAL : COPPER

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 2

9T83C9145G15

SKU: 9T83C9145G15
Manufacturer: General Electric
Weight: 820 lbs

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : COPPER

HZ : 60

TEMP RISE : 115

ENCLOSURE : NEMA 2

TYPE : LOW NOISE

OTHER : 12

9T10A1185

SKU: 9T10A1185
Manufacturer: General Electric

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 240/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 2

TYPE : K1

OTHER : DOE 2016

9T83C9315

SKU: 9T83C9315
Manufacturer: General Electric

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 400

SECONDARY VOLTAGE : 400Y/231

WINDING MATERIAL : COPPER

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 2

General Electric 112.5 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (9T49G0006G03)

SKU: 9T49G0006G03
Manufacturer: General Electric
Weight: 976 lbs

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : COPPER

HZ : 60

TEMP RISE : 80

ENCLOSURE : NEMA 2

TYPE : K-FACTOR

OTHER : 12

TAPS : 2 -4 -2.6%

9T83B3305

SKU: 9T83B3305
Manufacturer: General Electric

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 415

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 50

TEMP RISE : 150

ENCLOSURE : NEMA 2

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (SH3U0112KB2KG)

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (SH3U0112KB2KG)

SKU: SH3U0112KB2KG
Manufacturer: Hammond Power Solutions
Weight: 1000 lbs

KVA : 112.5

PHASE : THREE

WINDING MATERIAL : COPPER

TRADE NAME IF ANY : HPS SUPERCENTURION

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

TYPE : simple

General Electric 112.5 kVA Three Phase Dry Type Transformer: 480V - 600V (9T10A1125)

SKU: 9T10A1125
Manufacturer: GE Transformers
Manufacturer: General Electric

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 600

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 2

TYPE : K1

OTHER : DOE 2016

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 600V - 208Y/120V (SK3A0112PB3K)

Hammond Power Solutions 112.5 kVA Three Phase Dry Type Transformer: 600V - 208Y/120V (SK3A0112PB3K)

SKU: SK3A0112PB3K
Manufacturer: Hammond Power Solutions
Weight: 970 lbs

KVA : 112.5

PHASE : THREE

WINDING MATERIAL : COPPER

TRADE NAME IF ANY : HPS SYNERGY

TEMP RISE : 150°C

PRIMARY VOLTAGE : 600

SECONDARY VOLTAGE : 208Y/120

TYPE : simple

9T83B3876

SKU: 9T83B3876
Manufacturer: General Electric
Weight: 904 lbs

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 2

OTHER : 12

KVA : 112.5

PHASE : THREE

PRIMARY VOLTAGE : 440

SECONDARY VOLTAGE : 220Y/127

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 115

ENCLOSURE : NEMA 2

TYPE : GENERAL PURPOSE

Used & Reconditioned
Electrical Equipment

112.5 kVA Dry-Type Transformers

In Stock Since 1973

112.5 kVA Transformers | 3-Phase Step-Up & Step-Down Units.

Weight 400–1,200 lbs depending on copper or aluminum windings. Most popular: 480V to 208Y/120V. K-Factor rated K-1 through K-20, harmonic mitigating, low-noise (-3 dB), and autotransformer configurations. 50/60 Hz dual-rated models available.

✔ 438+ units in inventory    ✔ NEMA 1, 2, 3R, and 3R Heavy Duty enclosures    ✔ Reconditioned units backed by warranty

Request a Quote Contact Support Used & Reconditioned

 

Technical Specifications of a 112.5 kVA Transformer

The table below covers the full specification range across the 112.5 kVA dry-type transformer inventory we carry and source.

Parameter Specification
Power Rating 112.5 kVA
Transformer Type Dry-Type (air-cooled, no liquid insulation)
Phase Three-Phase (3Ø) all inventory units are 3-phase
Frequency 60 Hz standard; 50 Hz and 50/60 Hz on select models
Primary Voltage 208V, 220V, 240V, 380V, 400V, 415V, 440V, 460V, 480V, 575V, 600V, 2400V, 4160V
Secondary Voltage 208Y/120V, 480Y/277V, 240V, 240/120V, 220Y/127V, 480V, 400Y/231V, 380Y/219V, 240D, 600V and others
Temperature Rise 80°C, 115°C, 130°C, or 150°C above 40°C ambient
Insulation Class Class H (220°C)
Winding Material Aluminium (Al) or Copper (Cu) – both available across inventory
Enclosure Types NEMA 1, NEMA 2, NEMA 3R, NEMA 3R Heavy Duty, Indoor
Transformer Types General Purpose Ventilated, K-Factor (K-1, K-4, K-13, K-20), Harmonic Mitigating, Low Noise (–3 dB), Ultra Energy Efficient, Drive Isolation, Autotransformer, Encapsulated
Compliance DOE 2016, UL Listed, NEC Article 450
Manufacturers General Electric, Hammond Power Solutions, Rex Power Magnetics, Acme Electric, Jefferson Electric, EGS/SolaHD, Federal Pacific, MGM
Condition Available New (listed online); Used & Reconditioned available upon request via RFQ
Ships To All 50 U.S. states

Bruce Electric also supports specialty and custom transformer configurations depending on manufacturer availability and application requirements.

 

112.5 kVA Transformer Weight

Weight varies by phase, winding material, and enclosure. Use the table below for freight planning and structural load assessment. For certified dimensions and exact shipping weight, request the manufacturer datasheet with your quote.

Configuration Approx. Weight Notes
3-Phase, Aluminum Wound, NEMA 1/2 ~600–900 lbs Most common configuration in inventory
3-Phase, Copper Wound, NEMA 1/2 ~800–1,100 lbs Higher conductivity; preferred for long service life
NEMA 3R / NEMA 3R Heavy Duty Adder +75–150 lbs Added for outdoor weatherproof enclosure types
Encapsulated Units Varies by model Request certified weight per unit from datasheet

 

112.5 kVA Transformer Amps

Output amps depend on secondary voltage and phase configuration.

Formulas:

Three-phase: Amps = 112,500 ÷ (Volts × 1.732)

Single-phase: Amps = 112,500 ÷ Volts.

The tables below cover primary amps and secondary amps for the voltage levels present in our 112.5 kVA transformer inventory. Use these values for overcurrent device sizing per NEC Article 450, feeder conductor ampacity selection, and panel schedule design. Always verify against the unit nameplate before finalizing protection settings.

112.5 kVA Transformer Primary Amps

Primary Voltage Phase Formula Primary Amps
480V 112,500 ÷ (480 × 1.732) ~135 A
208V 112,500 ÷ (208 × 1.732) ~312 A
600V 112,500 ÷ (600 × 1.732) ~108 A
240V 112,500 ÷ (240 × 1.732) ~271 A
440V 112,500 ÷ (440 × 1.732) ~148 A
415V 112,500 ÷ (415 × 1.732) ~157 A
380V 112,500 ÷ (380 × 1.732) ~171 A
2400V 112,500 ÷ (2400 × 1.732) ~27 A
4160V 112,500 ÷ (4160 × 1.732) ~16 A

 

112.5 kVA Transformer Secondary Amps

Secondary Voltage Phase Formula Secondary Amps
208Y/120V 112,500 ÷ (208 × 1.732) ~312 A
480Y/277V 112,500 ÷ (480 × 1.732) ~135 A
240V 112,500 ÷ (240 × 1.732) ~271 A
240/120V 112,500 ÷ (240 × 1.732) ~271 A
220Y/127V 112,500 ÷ (220 × 1.732) ~295 A
480V 112,500 ÷ (480 × 1.732) ~135 A
400Y/231V 112,500 ÷ (400 × 1.732) ~162 A
380Y/219V 112,500 ÷ (380 × 1.732) ~171 A
240D / 240D/120CT 112,500 ÷ (240 × 1.732) ~271 A
600V 112,500 ÷ (600 × 1.732) ~108 A

 

112.5 kVA Step-Up vs. Step-Down Transformer

A 112.5 kVA step-down transformer reduces voltage from primary to secondary most commonly 480V to 208Y/120V for North American commercial power distribution. A 112.5 kVA step-up transformer increases voltage, for example from 208V to 480Y/277V, to feed higher-voltage equipment from a lower-voltage source. In most dry-type designs, the same physical unit can serve either function depending on wiring but always specify intended primary and secondary voltage to ensure correct nameplate design, warranty coverage, and NEC compliance.

Common Step-Down Configurations

Primary (Source) Secondary (Load) Phase Typical Application
480V 208Y/120V ( Most Popular ) Commercial panels, office buildings, retail
480V 480Y/277V Lighting distribution, isolation applications
480V 240D Industrial motor loads, legacy delta systems
480V 250D/120CT Resistance welding, specialized process equipment
600V 480Y/277V Canadian service entry, cross-border industrial
600V 208Y/120V Direct 600V to utilization voltage
480V 240/120V Residential-style service in commercial buildings
240V 120/115/110V Control circuit voltage reduction

Common Step-Up Configurations

Primary (Source) Secondary (Load) Phase Typical Application
208V 480Y/277V Powering 480V equipment from 208V service
240V 480Y/277V VFD feeds, motor starters needing higher voltage
380V 480V International equipment on U.S. service
208V 480V Single-phase step-up for specific equipment feeds

 

Key Features of Our 112.5 kVA Dry-Type Transformers

1. Three-phase configurations across all standard and specialty types

2. Air-cooled dry-type construction no oil, no liquid maintenance, no spill risk

3. Copper or aluminium windings to balance performance requirements and project budget

4. NEMA 1, NEMA 2, and NEMA 3R enclosures for indoor and outdoor installation

5. DOE 2016 compliant on all new units; Super-Efficient models available (Acme TPC3-series, Hammond HPS Super centurion)

6. Specialty types: K-Factor rated, Harmonic Mitigating, Low Noise (–3 dB), and Autotransformer configurations in inventory

7. 50 Hz / 60 Hz dual-rated models available for international equipment compatibility

 

Applications of 112.5 kVA Dry-Type Transformers

1. Commercial buildings and office facilities – 480V to 208Y/120V step-down for tenant panels and lighting

2. Manufacturing and industrial plants – motor control centers, CNC equipment, and process line distribution

3. Healthcare and medical facilities – isolated power systems for ORs and critical care areas, often paired with UPS systems

4. Data centers and IT infrastructure – 480V to 208V step-down feeding server PDUs and UPS bypass panels

5. Transportation and infrastructure – transit stations, airports, and rail facility power distribution

6. Construction sites – temporary 480V-to-208Y/120V distribution for site panels and temporary power

 

Why Choose Bruce Electric for 112.5 kVA Transformers

Bruce Electric is a trusted supplier of 112.5 kVA dry-type transformers, offering a wide selection of new units to meet diverse project specifications. With over 50 years of industry experience, we provide fast access to in-stock transformers in multiple voltage configurations, phases, and NEMA enclosure types. Customers benefit from expert technical support for accurate sizing and configuration, and equipment that meets UL, DOE, and NEC standards. Used and reconditioned 112.5 kVA transformers are available upon request through our sourcing and RFQ process contact us for current availability. Backed by nationwide shipping and warranty coverage, Bruce Electric delivers reliable, cost-effective transformer solutions with quick turnaround times.

 

FAQs

Q1. What are the secondary amps of a 112.5 kVA transformer at 208V?

For a three-phase secondary at 208Y/120V: Amps = 112,500 ÷ (208 × 1.732) = approximately 312 A. For single-phase at 240V: 112,500 ÷ 240 = approximately 469 A. Always confirm against the nameplate for final NEC 450.3 overcurrent device sizing.

Q2. What are the primary amps of a 112.5 kVA transformer at 480V?

At a 480V three-phase primary: Amps = 112,500 ÷ (480 × 1.732) = approximately 135 A. This figure is used for feeder conductor sizing and upstream overcurrent protection selection per NEC Article 450.

Q3. How much does a 112.5 kVA transformer weigh?

Weight typically ranges from 400 to 1,200 lbs depending on phase (single vs. three-phase), winding material (copper vs. aluminum), and enclosure type. Three-phase copper-wound units in NEMA 1 enclosures are at the upper end. Always request certified shipping weight for structural loading and freight planning.

Q4. What is the typical price of a 112.5 kVA transformer?

New unit pricing varies by manufacturer, voltage configuration, winding material, and efficiency class. Contact Bruce Electric for a current quote. Used and reconditioned 112.5 kVA transformers are available upon request through our RFQ process and can offer 20–50% savings versus new.

Q5. Is a 112.5 kVA transformer DOE 2016 compliant?

Yes. All new low-voltage dry-type distribution transformers sold in the U.S. must meet DOE 2016 minimum efficiency standards. Super-Efficient series units (Acme TPC3-series, Hammond HPS Super-centurion) exceed these minimums and deliver additional lifecycle energy savings.