75 kVA Transformers

A 75 kVA dry-type transformer is a versatile and widely used solution for medium-capacity power distribution across commercial and industrial applications. Designed for safe, efficient, and maintenance-free operation, these transformers are ideal for indoor and outdoor installations where reliability and performance are critical.

 

Bruce Electric Equipment has been distributing dry-type transformers across the United States since 1973. We stock new, reconditioned and used 75 kVA transformer units from leading manufacturers including GE, ABB, Acme Electric, Hammond Power Solutions, and Sola HD, covering all standard voltage configurations and enclosure types.

Showing 1–15 of 723 results

Acme AE010075

Acme AE010075

SKU: AE010075
Manufacturer: Acme Electric
Weight: 3.5 lbs

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE01-0075

Acme Electric 75 kVA Single Phase Dry Type Transformer: 120 X 240V - 24V (AE010075F2)

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE01-0075-F2

Acme AE020075

Acme AE020075

SKU: AE020075
Manufacturer: Acme Electric
Weight: 4 lbs

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 200/220/440 208/230/460 240/480

SECONDARY VOLTAGE : 23/110 24/115 25/120

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE02-0075

AE020075F2

SKU: AE020075F2
Manufacturer: Acme Electric

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 200/220/440 208/230/460 240/480

SECONDARY VOLTAGE : 23/110 24/115 25/120

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE02-0075-F2

Acme Electric 75 kVA Single Phase Dry Type Transformer: 240 X 480V - 24V (AE030075)

Acme Electric 75 kVA Single Phase Dry Type Transformer: 240 X 480V - 24V (AE030075)

SKU: AE030075
Manufacturer: Acme Electric
Weight: 3.5 lbs

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 240 X 480

SECONDARY VOLTAGE : 24

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE03-0075

Acme Electric 75 kVA Single Phase Dry Type Transformer: 240/480/230/460 220/440V - 120/115/110V (AE060075)

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 240/480/230/460 220/440

SECONDARY VOLTAGE : 120/115/110

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE06-0075

Acme Electric 75 kVA Single Phase Dry Type Transformer: 240/480/230/460 220/440V - 120/115/110V (AE060075F2)

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 240/480/230/460 220/440

SECONDARY VOLTAGE : 120/115/110

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : AE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : AE06-0075-F2

CE010075

SKU: CE010075
Manufacturer: Acme Electric
Weight: 3.5 lbs

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 120 X 240

SECONDARY VOLTAGE : 24

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : CE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : CE01-0075

Acme Electric 75 kVA Single Phase Dry Type Transformer: 240 X 480V - 24V (CE030075)

SKU: CE030075
Manufacturer: Acme Electric
Weight: 3.5 lbs

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 240 X 480

SECONDARY VOLTAGE : 24

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : CE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : CE03-0075

CE060075

SKU: CE060075
Manufacturer: Acme Electric
Weight: 3.6 lbs

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 240 X 480/ 230 X 460/ 220 X 440

SECONDARY VOLTAGE : 120/115/110

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : CE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : CE06-0075

CE060075F2

SKU: CE060075F2
Manufacturer: Acme Electric

KVA : 75

PHASE : SINGLE

PRIMARY VOLTAGE : 240 X 480/ 230 X 460/ 220 X 440

SECONDARY VOLTAGE : 120/115/110

WINDING MATERIAL : COPPER

HZ : 50/60

TEMP RISE : 55

ENCLOSURE : OPEN STYLE

TYPE : CE SERIES INDUSTRIAL CONTROL TRANSFORMERS

OLD PART NUMBER : CE06-0075-F2

Acme Electric 75 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (CMT533144S)

SKU: CMT533144S
Manufacturer: Acme Electric
Weight: 760 lbs

KVA : 75

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : COPPER

HZ : 60

ENCLOSURE : NEMA 1

TYPE : HARMONIC MITIGATING TRANFORMERS

OLD PART NUMBER : CMT-53314-4S

OTHER : 81-E

Acme Electric 75 kVA Three Phase Dry Type Transformer: 230V - 230Y/133V (DTFA0754S)

SKU: DTFA0754S
Manufacturer: Acme Electric
Weight: 525 lbs

KVA : 75

PHASE : THREE

PRIMARY VOLTAGE : 230

SECONDARY VOLTAGE : 230Y/133

HZ : 60

TEMP RISE : 150

ENCLOSURE : ENCAPSULATED

TYPE : DRIVE ISOLATION TRANSFORMER

OLD PART NUMBER : DTFA-075-4S

OTHER : E

DTGA0754S

SKU: DTGA0754S
Manufacturer: Acme Electric
Weight: 570 lbs

KVA : 75

PHASE : THREE

PRIMARY VOLTAGE : 460

SECONDARY VOLTAGE : 230Y/133

HZ : 60

TEMP RISE : 150

TYPE : DRIVE ISOLATION TRANSFORMER

OLD PART NUMBER : DTGA-075-4S

OTHER : E

Acme Electric 75 kVA Three Phase Dry Type Transformer: 460V - 460Y/266V (DTGB0754S)

SKU: DTGB0754S
Manufacturer: Acme Electric
Weight: 570 lbs

KVA : 75

PHASE : THREE

PRIMARY VOLTAGE : 460

SECONDARY VOLTAGE : 460Y/266

HZ : 60

TEMP RISE : 150

TYPE : DRIVE ISOLATION TRANSFORMER

OLD PART NUMBER : DTGB-075-4S

OTHER : E

Used & Reconditioned
Electrical Equipment

 

Technical Specifications of a 75 kVA Transformer

The table below covers the full range of specifications available across the 75 KVA dry-type transformers we carry and source.

Power Rating 75 KVA
Transformer Type Dry-Type (air-cooled)
Phase Single-phase (1Ø) and Three-phase (3Ø)
Frequency 50 Hz / 60 Hz
Temperature Rise 50°C, 80°C, 115°C, or 150°C above 40°C ambient
Winding Material Copper (Cu) or Aluminium (Al)
Enclosure Types NEMA 1 (standard indoor), NEMA 2 (drip-proof), NEMA 3R (outdoor/rainproof)
Insulation Class Class H (220°C)
Compliance UL Listed, DOE Energy Efficient (TP-1 / DOE 2016), CSA available
Condition Available New, Reconditioned, Used and Refurbished
Service Coverage Ships across all 50 U.S. states

 

75 KVA Transformer Weight

A 75 KVA dry-type transformer typically weighs between 450 and 750 lbs depending on phase (single vs three), winding material (copper vs aluminium), enclosure type, and manufacturer. Three-phase copper-wound NEMA 3R units are at the heavier end of the range

• Three-phase copper: 550–720 lbs

• Three-phase aluminum: 460–600 lbs

• Single-phase copper: 450–580 lbs

• NEMA 3R enclosure adds: 50–100 lbs

 

75 kVA Transformer Amps

The ampere output of a 75 KVA transformer depends on the secondary voltage and phase. Use these formulas: Three-phase: Amps = 75,000 ÷ (Volts × 1.732) | Single-phase: Amps = 75,000 ÷ Volts

Secondary Voltage Phase Calculation Output Amps
Three-Phase (3Ø) Output
208Y/120V 75,000 ÷ (208 × 1.732) ~208 A
240V 75,000 ÷ (240 × 1.732) ~180 A
480V 75,000 ÷ (480 × 1.732) ~90 A
600V 75,000 ÷ (600 × 1.732) ~72 A
380Y/220V 75,000 ÷ (380 × 1.732) ~114 A
415Y/240V 75,000 ÷ (415 × 1.732) ~104 A
Single-Phase (1Ø) Output
120/240V 75,000 ÷ 240 ~313 A
240V 75,000 ÷ 240 ~313 A
480V 75,000 ÷ 480 ~156 A
120V 75,000 ÷ 120 ~625 A

 

75 KVA Step-Up vs. Step-Down Transformer

A 75 KVA step-down transformer reduces voltage most commonly from 480V to 208Y/120V. A 75 KVA step-up transformer increases voltage, for example from 208V to 480V. In most cases the same transformer unit can serve either function; the designation depends on which winding is connected to the source. A 75 KVA dry-type transformer typically weighs between 450 and 750 lbs, depending on configuration.

Common Step-Down Configurations

Primary (Source) Secondary (Load) Phase Typical Application
480V 208Y/120V Most Popular Commercial building panels, office fitouts
480V 240/120V Residential-style service in commercial builds
480V 480Y/277V Lighting systems, isolation applications
600V 480V Canadian service entry, industrial retrofit
4160V 480V / 208Y/120V Medium-voltage distribution step-down
2400V 480V / 208Y/120V Older facility distribution systems

Common Step-Up Configurations

Primary (Source) Secondary (Load) Phase Typical Application
208V 480V Powering 480V equipment from 208V service
240V 480V 1Ø or 3Ø VFD feeds, motor starters requiring higher voltage
480V 600V Equipment rated for Canadian 600V service

 

Key Features of Our 75 kVA Dry-Type Transformers

• Designed for indoor and Outdoor installations with compact footprint

• Low maintenance operation with no liquid handling required

• Reliable voltage transformation for stable system performance

• Multiple voltage configurations for system flexibility

• Efficient thermal performance for long service life

• Built to meet modern electrical standards and efficiency requirements

 

Applications of 75 kVA Dry Type Transformers

75 kVA transformers are widely used in:

Commercial buildings and office facilities

Manufacturing and industrial plants

• HVAC systems and mechanical equipment

• Lighting and panel distribution systems

Data centers and electrical infrastructure

• Machinery and process equipment

 

Why Choose Bruce Electric for 75 kVA Transformers

Bruce Electric is a trusted supplier of 75 KVA dry-type transformers, offering a wide selection of new, surplus, reconditioned, and used units to meet diverse project needs. With over 50 years of industry experience, they provide fast access to in-stock transformers in multiple voltage configurations, phases, and NEMA enclosure types. Customers benefit from 20–50% cost savings, expert technical support for accurate sizing and configuration, and equipment that meets UL, DOE, and NEC standards. Backed by testing, warranty coverage, and nationwide shipping, Bruce Electric ensures reliable, cost-effective transformer solutions with quick turnaround times.

 

FAQs

Q1. What is the load capacity of a 75 kVA transformer?

A 75 kVA transformer can handle up to 75,000 VA (75 kVA) of apparent power. For continuous operation, it is recommended to load it to 80% capacity (~60 kVA) to prevent overheating and extend service life.

Q2. What does a 75 KVA transformer weigh?

A 75 KVA dry-type transformer typically weighs between 450 and 750 lbs (204–340 kg), depending on phase, winding material (copper or aluminium), and enclosure type such as NEMA 1 or NEMA 3R.

Q3. How many kW is 75 kVA?

The kW value of a 75 kVA transformer depends on the power factor. At a typical 0.8 power factor, 75 kVA equals 60 kW. At unity power factor (1.0), it equals 75 kW.

Q4. What is the difference between a 75 KVA step-up and step-down transformer?

A 75 KVA step-down transformer reduces voltage (e.g., 480V to 208Y/120V), while a step-up transformer increases voltage (e.g., 208V to 480V). The same transformer can often perform both functions depending on wiring configuration.

Q5. What frequency is a 75 KVA transformer rated for?

A 75 KVA transformer is typically rated for 60 Hz (standard in the U.S.) or 50 Hz (used internationally). Always match the transformer frequency with your power supply to ensure proper performance.