A 45 kVA dry type transformer is widely used for commercial, industrial, institutional, OEM, and light infrastructure power distribution applications requiring reliable voltage conversion, compact installation, and efficient low-voltage distribution. Common applications include panel distribution systems, HVAC equipment, machine tools, lighting systems, retail facilities, schools, healthcare buildings, construction projects, and industrial control systems.
At Bruce Electric Equipment Corp., we supply new 45 kVA transformers online and provide custom sourcing support for used, surplus, and reconditioned transformers through our RFQ process. Since 1973, Bruce Electric has specialized in dry type transformers and electrical distribution equipment from leading manufacturers including Acme Electric, Hammond Power Solutions (HPS), Eaton, GE, ABB, Schneider Electric / Square D, and SolaHD.
Showing 1–15 of 621 results
In addition to standard 480V to 208Y/120V configurations, Bruce Electric can source 45 kVA transformers for a wide range of specialty, international, and non-standard voltage requirements used across industrial facilities, OEM equipment, export systems, and retrofit projects.
Common available configurations include:
• 480V to 208Y/120V
• 600V to 208Y/120V
• 480V to 480Y/277V
• 208V to 480Y/277V
• 240V to 480Y/277V
• 480V to 240/120V
• 400Y/231V
• 415Y/240V
• 380Y/219V
• 600Y/347V
Available transformer types may include dry type distribution transformers, encapsulated transformers, isolation transformers, harmonic mitigating transformers, autotransformers, low-noise transformers, and non-ventilated transformers. Availability varies by manufacturer, winding material, enclosure type, and application requirements.
We support contractors, engineers, facility managers, OEMs, and industrial buyers with transformer sizing assistance, voltage matching, replacement sourcing, and nationwide shipping across the United States.
The specifications below represent common configurations available across 45 kVA dry type transformers. Actual specifications vary by manufacturer, transformer design, enclosure type, winding material, and application requirements.
| Specification | Details |
|---|---|
| Power Rating | 45 kVA (45,000 VA) |
| Transformer Type | Dry Type, Encapsulated, Isolation, Autotransformer |
| Phase | Single-Phase (1Ø) and Three-Phase (3Ø) |
| Frequency | 60 Hz standard; select 50/60 Hz models available |
| Winding Material | Copper and Aluminium |
| Enclosure Types | NEMA 1, NEMA 2, NEMA 3R, Stainless Steel |
| Temperature Rise | 115°C and 150°C configurations available |
| Cooling Method | Air-Cooled / Ventilated |
| Efficiency Compliance | DOE 10 CFR Part 431 |
| Available Conditions | New online; used and reconditioned via RFQ |
Bruce Electric also supports specialty and custom transformer configurations depending on manufacturer availability and application requirements.
All new 45 kVA dry type transformers supplied for U.S. applications must comply with DOE energy efficiency standards under 10 CFR Part 431. DOE-compliant transformers are designed to reduce core losses and improve operating efficiency, helping commercial and industrial facilities lower long-term energy costs. Bruce Electric supplies DOE-compliant transformer solutions for commercial buildings, manufacturing facilities, infrastructure projects, and electrical system upgrades.
The amp output of a 45 kVA transformer depends on voltage and phase configuration.
FLA = kVA × 1,000 ÷ (V × 1.732)
FLA = kVA × 1,000 ÷ V
| Voltage | Phase | Approximate Full Load Amps |
|---|---|---|
| 208Y/120V | 3Ø | 125 A |
| 240V | 3Ø | 108 A |
| 480V | 3Ø | 54 A |
| 600V | 3Ø | 43 A |
| 240V | 1Ø | 188 A |
| 480V | 1Ø | 94 A |
A 45 kVA transformer with a 480V primary and 208Y/120V secondary is one of the most common commercial distribution configurations used for panelboards, lighting loads, receptacle circuits, and HVAC systems.
A 45 kVA 3 phase transformer is commonly used in commercial and industrial power distribution systems where balanced three-phase power is required. Three-phase 45 kVA transformers are frequently installed in:
• Commercial office buildings
• Retail facilities
• HVAC systems
• Manufacturing equipment
• Motor control centers
• Schools and universities
• Healthcare facilities
• Construction and temporary power systems
• Industrial process equipment
Bruce Electric supplies three-phase 45 kVA transformers in ventilated, encapsulated, low-noise, harmonic mitigating, and non-ventilated designs for indoor and outdoor installations.
45 kVA transformers are available for both step-up and step-down voltage conversion applications.
| Primary Voltage | Secondary Voltage | Application |
|---|---|---|
| 480V | 208Y/120V | Commercial distribution |
| 600V | 208Y/120V | Industrial and Canadian systems |
| 480V | 240D | Machinery and motor loads |
| 480V | 240/120V | Mixed lighting and receptacle loads |
| Primary Voltage | Secondary Voltage | Application |
|---|---|---|
| 208V | 480Y/277V | 480V equipment operation |
| 240V | 480Y/277V | Industrial systems |
| 240V | 416Y/240V | Specialty equipment |
| 208V | 480V | Machine tools and OEM systems |
Many dry type transformers can support reverse-feed operation when properly configured and approved by the manufacturer.
45 kVA isolation transformers are commonly used to separate sensitive electrical equipment from the primary power source while reducing electrical noise, transient voltage disturbances, and grounding issues.
Typical isolation transformer applications include:
• Medical equipment
• Data centers
• Industrial automation systems
• CNC machinery
• Audio/video systems
• UPS systems
• Sensitive electronic loads
Bruce Electric offers isolation transformer solutions from leading transformer manufacturers for commercial and industrial applications.
Transformer dimensions and weight vary depending on manufacturer, enclosure type, winding material, and transformer construction.
| Configuration | Approximate Weight |
|---|---|
| 3Ø Copper Wound | 350–650 lbs |
| 3Ø Aluminum Wound | 300–550 lbs |
| Encapsulated NEMA 3R | Higher due to enclosure construction |
| Dimension | Typical Range |
|---|---|
| Width | 24–36 inches |
| Depth | 18–30 inches |
| Height | 32–48 inches |
Always verify certified outline drawings and manufacturer specifications before installation planning.
A 45 kVA transformer provides 45,000 VA (volt-amperes) of apparent power capacity for commercial and industrial electrical distribution systems. Actual load capacity depends on voltage, phase configuration, power factor, ambient temperature, and application type.
General load guidance includes:
• Nameplate capacity: 45 kVA
• Recommended continuous loading: approximately 80%
• Suitable for panel distribution, HVAC systems, lighting loads, motor loads, and equipment feeds
• Available in both single-phase and three-phase configurations
Bruce Electric can help determine the correct transformer sizing and voltage configuration based on your application requirements and load calculations.
When installing a 45 kVA transformer, important considerations include:
• NEC clearance requirements
• Ventilation and airflow
• Indoor and outdoor installation environment
• NEMA enclosure selection
• Conductor sizing and overcurrent protection
• Noise-sensitive installation areas
• Voltage compatibility
• Future load expansion capacity
Outdoor or harsh-environment installations may require NEMA 3R or stainless-steel transformer enclosures.
45 kVA transformers are commonly used across:
• Retail stores
• Restaurants
• Schools and universities
• Industrial automation systems
• HVAC equipment
• Lighting distribution systems
• Panelboards and branch circuits
• OEM machinery systems
Bruce Electric supplies dry type transformers for commercial, industrial, institutional, and OEM applications throughout the United States.
Bruce Electric has supplied dry type transformers and electrical distribution equipment since 1973. We provide:
• New 45 kVA transformers available online
• Custom sourcing for used and reconditioned transformers
• Multiple voltage configurations
• Step-up and step-down transformer solutions
• Isolation and harmonic mitigating transformers
• Copper and aluminum winding options
• Indoor and outdoor transformer configurations
• Technical support for sizing and compatibility
• Nationwide shipping across the United States
Our team works with contractors, engineers, maintenance teams, procurement departments, OEM manufacturers, and facility managers to help source reliable transformer solutions for both new installations and replacement applications.
A 45 kVA transformer at 480V three-phase outputs approximately 54 amps at full load. A 208Y/120V three-phase secondary outputs approximately 125 amps. Actual amp output depends on voltage and phase configuration.
Most 45 kVA dry type transformers weigh between approximately 300 and 650 lbs depending on winding material, enclosure type, and transformer design.
45 kVA transformers are commonly used for commercial power distribution, HVAC systems, lighting systems, industrial equipment, panelboards, schools, healthcare facilities, and OEM machinery applications.
One of the most common configurations is 480V primary to 208Y/120V secondary for commercial building power distribution.
Bruce Electric primarily lists new electrical equipment online. Used, surplus, and reconditioned 45 kVA transformers are available through our RFQ and custom sourcing process.
Related Products