30 kVA Transformers

A 30 kVA transformer is a proven choice for commercial and light-industrial power distribution when a standard 25 kVA unit does not provide enough capacity, but a larger 45 kVA transformer is unnecessary. Bruce Electric supplies primarily three-phase dry-type 30 kVA transformers for high-demand applications such as 480V to 208Y/120V panel distribution, HVAC and mechanical systems, light manufacturing equipment, office and retail buildouts, data rooms, and replacement projects.

 

Our 30 kVA inventory includes indoor NEMA 1 and NEMA 2 units, outdoor NEMA 3R and encapsulated options, copper and aluminum windings, and leading brands including GE, Hammond Power Solutions, Rex Power Magnetics, Federal Pacific, Acme Electric, MGM, and More. New transformers are available online. For used, surplus, or reconditioned 30 kVA transformers, submit an RFQ or contact Bruce Electric for current sourcing options.

Primary Voltage

Secondary Voltage

Showing 1–15 of 676 results

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240D, 120 WITH CENTER TAPV (HT5F30AS)

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 240D, 120 WITH CENTER TAP

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 115

ENCLOSURE : NEMA 3R ENCAPSULATED

TYPE : NON-VENTILATED AUTOMATION TRANSFORMER

TAPS : 2, 5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (HT1F30AS)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (HT1F30AS)

SKU: HT1F30AS
Manufacturer: EGS/SOLAHD
Weight: 696 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 115

ENCLOSURE : NEMA 3R ENCAPSULATED

TYPE : NON-VENTILATED AUTOMATION TRANSFORMER

TAPS : 2, 5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 240V - 480Y/277V (ET85H30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 240V - 480Y/277V (ET85H30S)

SKU: ET85H30S
Manufacturer: EGS/SOLAHD
Weight: 295 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 240

SECONDARY VOLTAGE : 480Y/277

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 208V - 480Y/277V (ET84H30)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 208V - 480Y/277V (ET84H30)

SKU: ET84H30
Manufacturer: EGS/SOLAHD
Weight: 295 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 208

SECONDARY VOLTAGE : 480Y/277

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 480Y/277V (ET81H30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 480Y/277V (ET81H30S)

SKU: ET81H30S
Manufacturer: EGS/SOLAHD
Weight: 295 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 480Y/277

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 380Y/220V (ET79H30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 380Y/220V (ET79H30S)

SKU: ET79H30S
Manufacturer: EGS/SOLAHD
Weight: 295 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 380Y/220

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 240V - 208Y/120V (ET6H30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 240V - 208Y/120V (ET6H30S)

SKU: ET6H30S
Manufacturer: EGS/SOLAHD
Weight: 295 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 240

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240DV (ET5HF30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240DV (ET5HF30S)

SKU: ET5HF30S
Manufacturer: EGS/SOLAHD
Weight: 292 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 240D

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 115

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER WITH REDUCED CAPACITY CENTER TAP

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240DV (ET5H30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240DV (ET5H30S)

SKU: ET5H30S
Manufacturer: EGS/SOLAHD
Weight: 292 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 240D

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER WITH REDUCED CAPACITY CENTER TAP

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240DV (ET5H30)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 240DV (ET5H30)

SKU: ET5H30
Manufacturer: EGS/SOLAHD
Weight: 292 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 240D

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER WITH REDUCED CAPACITY CENTER TAP, UNSHEILDED

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ET2HF30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ET2HF30S)

SKU: ET2HF30S
Manufacturer: EGS/SOLAHD
Weight: 292 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 115

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ET2HB30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ET2HB30S)

SKU: ET2HB30S
Manufacturer: EGS/SOLAHD
Weight: 376 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 80

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 208V - 208Y/120V (ET3H30S)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 208V - 208Y/120V (ET3H30S)

SKU: ET3H30S
Manufacturer: EGS/SOLAHD
Weight: 295 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 208

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ET2H30SCU)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ET2H30SCU)

SKU: ET2H30SCU
Manufacturer: EGS/SOLAHD
Weight: 305 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : COPPER

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ESTH25)

EGS/SOLAHD 30 kVA Three Phase Dry Type Transformer: 480V - 208Y/120V (ESTH25)

SKU: ESTH25
Manufacturer: EGS/SOLAHD
Weight: 250 lbs

KVA : 30

PHASE : THREE

PRIMARY VOLTAGE : 480

SECONDARY VOLTAGE : 208Y/120

WINDING MATERIAL : ALUMINUM

HZ : 60

TEMP RISE : 150

ENCLOSURE : NEMA 1

TYPE : VENTILATED DISTRIBUTION TRANSFORMER

TAPS : 2, 2.5% FCAN/4, 2.5% FCBN

Used & Reconditioned
Electrical Equipment

 

30 kVA Dry Type Transformer Specifications

 

Parameter Value / Range
Power Rating 30 kVA
Type Dry-Type
Phase Three-phase (1Ø available – contact for availability)
Frequency 60 Hz standard; 50/60 Hz on select Acme Electric and Rex Power Magnetics models
Primary Voltage 208V — 600V (model dependent)
Secondary Voltage 208Y/120V — 600Y/347V (model dependent)
Temperature Rise 80°C, 115°C, 130°C, 135°C, or 150°C (commercial encapsulated units may be rated 180°C)
Winding Material Copper or Aluminium
Enclosures NEMA 1, NEMA 2, NEMA 3R, NEMA 3R Encapsulated, NEMA 3R Stainless Steel, NEMA 4
Standard Taps 2 at 2.5% FCAN / 4 at 2.5% FCBN; 6-tap configurations on select Federal Pacific models
Insulation Class Class H (180°C rated insulation)
Compliance UL Listed; DOE 2016 / 10 CFR Part 431 (confirmed on GE units; verify per manufacturer for others)
Condition New (online); used/reconditioned available upon request

 

30 kVA Transformer Full-Load Amps

Full-load amperage is determined by secondary voltage and phase configuration. Use the formulas below to calculate amps for any 30 kVA unit:

Three-phase: Amps = 30,000 ÷ (Volts × 1.732)

Single-phase: Amps = 30,000 ÷ Volts

 

Three-Phase Full-Load Amps

Voltage Phase Calculation Full-Load Amps
208V 30,000 ÷ (208 × 1.732) ~83.3 A
240V 30,000 ÷ (240 × 1.732) ~72.2 A
480V 30,000 ÷ (480 × 1.732) ~36.1 A
600V 30,000 ÷ (600 × 1.732) ~28.9 A
380V 30,000 ÷ (380 × 1.732) ~45.6 A

 

Single-Phase Full-Load Amps

Voltage Phase Calculation Full-Load Amps
120V 30,000 ÷ 120 ~250 A
240V 30,000 ÷ 240 ~125 A
480V 30,000 ÷ 480 ~62.5 A

 

These are full-load reference values only. Overcurrent protection and conductor sizing must be confirmed using NEC Article 450, NEC 450.3, NEC 310.15, the transformer nameplate, conductor material, ambient temperature, conduit fill, and local Authority Having Jurisdiction requirements. Use Bruce Electric’s kVA Calculator to confirm sizing before submitting an RFQ.

 

30 kVA Transformer Dimensions and Weight

30 kVA transformer dimensions and weights vary by manufacturer, phase, enclosure, winding material, steel construction, taps, and accessories. Bruce Electric’s product data includes NEMA 1, NEMA 2, NEMA 3R, encapsulated, heavy-duty, stainless steel, and select specialty enclosures, so there is no single standard physical size.

 

Configuration Enclosure Typical Size Range Approx. Weight
Three-phase aluminium NEMA 2 28–38″ H × 18–24″ W × 14–20″ D 250–380 lbs
Three-phase copper NEMA 2 28–38″ H × 18–24″ W × 14–20″ D 300–450 lbs
Three-phase NEMA 3R 30–40″ H × 20–26″ W × 16–22″ D 320–480 lbs
Single-phase NEMA 2 18–28″ H × 14–18″ W × 10–16″ D 150–280 lbs
Single-phase NEMA 3R 20–30″ H × 16–20″ W × 12–18″ D 190–320 lbs

 

These are planning ranges, not certified dimensions. Always verify exact dimensions and weights from the manufacturer datasheet before floor loading, conduit routing, pad layout, or final installation. At these weights, a pallet jack, forklift, or properly rated lifting method should be used for positioning.

 

30 kVA Transformer Voltage Configurations

The 30 kVA units in our inventory cover the following primary-to-secondary voltage configurations:

Three-Phase 30 kVA Step-Down Configurations

Primary Secondary Common Use Case
480V 208Y/120V ★ Most Common Commercial panel boards, office buildings, retail, HVAC, general branch circuit distribution
480V 240D Industrial motor feeds, manufacturing equipment, delta-connected loads
480V 240/120V (with center tap) Lighting panels, mixed single-phase and three-phase loads, jobsite distribution
480V 250D/120CT Legacy delta systems requiring center-tap neutral for lighting circuits
480V 480Y/277V Isolation service, 277V lighting feeds, step-down for grounded wye distribution
480V 380Y/220V Imported European and international equipment operating on 380V three-phase
480V 400Y/231V IEC-standard machinery, European-spec equipment installed in US facilities
480V 220Y/127V Japanese and international equipment requiring 220V/127V service
480V 240Y/139V Specialty international equipment with non-standard wye voltage requirements
480V 230Y/133V European and international equipment requiring 230V phase-to-neutral service
600V 208Y/120V Canadian primary service stepping down to standard US distribution voltage
600V 480Y/277V Canadian service entry feeding 480V industrial equipment or 277V lighting
600V 480V Canadian primary service to 480V delta-connected industrial loads
240V 208Y/120V Facilities with 240V primary service requiring 208Y/120V panel distribution
240V 480Y/277V Step-up from 240V service to 480V equipment or 277V lighting systems
208V 208Y/120V Isolation service; re-referencing existing 208V service with a grounded neutral
380V 220Y/127V International primary service feeding European-standard 220V equipment
380V 208Y/120V International facilities requiring US-standard 208Y/120V from 380V service

 

Three-Phase 30 kVA Step-Up Configurations

Primary Secondary Common Use Case
208V 480Y/277V Powering 480V-rated equipment or 277V lighting from a 208V building service
208V 480V Feeding 480V delta-connected motors, VFDs, or compressors from 208V service
240V 480V Stepping up 240V service to 480V delta loads in industrial retrofit projects
240V 480Y/277V Stepping up 240V service to feed 480V wye-connected equipment or 277V lighting

 

Most dry-type units can serve in either step-up or step-down orientation, confirm reverse-feed compatibility with the manufacturer datasheet before step-up installation.

International and specialty configurations are also stocked, including 380V → 220Y/127V, 480V → 220Y/127V, 480V → 230Y/133V, and 480V → 240Y/139V for imported equipment applications.

Used and reconditioned 30 kVA transformers in common configurations particularly 480V to 208Y/120V – can be sourced through our RFQ and custom sourcing process. Contact Bruce Electric for availability.

 

Applications of 30 kVA Dry Type Transformers

A 30 kVA transformer sits between the 25 kVA and 45 kVA ratings, making it a common choice for medium-density commercial distribution and light industrial loads.

1. Commercial Buildings and Office. Office suites, retail spaces, and commercial buildings requiring 480V to 208Y/120V panel distribution for lighting, receptacles, and HVAC loads.

2. Light Industrial and Manufacturing. Machine tools, conveyor systems, small motor loads, and general-purpose equipment requiring reliable three-phase voltage conversion.

3. Data Centers and IT Infrastructure. Server rack distribution, UPS systems, and IT equipment requiring clean 208Y/120V power from 480V service.

4. Healthcare and Medical Facilities. Medical equipment, diagnostic imaging, and facility distribution requiring isolated and regulated power.

5. Construction and Temporary Power. Jobsite distribution panels, temporary lighting, and portable equipment requiring robust 30 kVA capacity.

6. Retrofit and Replacement. Upgrading aging transformers without redesigning the existing electrical distribution system or changing panel configurations.

 

How to Select the Right 30 kVA Transformer

1. Confirm your kVA requirement. Total connected load should be calculated and converted to kVA before assuming 30 kVA is the correct size. Use BEE’s kVA Calculator to verify. If your load is close to the boundary between ratings, size up.

2. Identify primary and secondary voltage. Match to your available supply voltage (208V, 240V, 480V, or 600V) and your required downstream voltage. This combination narrows the field significantly.

3. Indoor or outdoor? NEMA 1 and NEMA 2 are for dry indoor locations. NEMA 3R or NEMA 3R encapsulated are required for outdoor, damp, or wet locations. Only rated outdoor enclosures should be used in exposed installations.

4. Copper or aluminium windings? Aluminium is standard and cost-effective for most applications. Copper is preferred for high-cycle, critical installations, or where the project specification calls for copper in kind.

5. Does the load have significant harmonics? VFDs, UPS systems, computers, and electronic ballasts all generate harmonic currents. For these applications, specify a K-Factor rated unit (K-4, K-13, or K-20 depending on load mix) rather than a standard general-purpose unit.

6. Check tap requirements. Standard units include 2 FCAN / 4 FCBN taps at 2.5%. If site utility voltage consistently runs above or below nominal, confirm that the tap range is sufficient to compensate.

 

30 kVA Transformer Installation Considerations

1. NEC Compliance. 30 kVA dry-type transformer installations must comply with NEC Article 450, including requirements for overcurrent protection, ventilation, accessibility, and installation conditions. Final compliance should be confirmed with the local Authority Having Jurisdiction.

2. Overcurrent Protection. Primary overcurrent protection must be sized according to NEC 450.3 and the transformer’s rated current. At 480V three-phase, a 30 kVA transformer draws approximately 36.1 amps at full load. Protection sizing depends on the transformer configuration and whether both primary and secondary protection are provided.

3. Conductor Sizing. Primary and secondary conductors should be sized per NEC 310.15 using the correct conductor material, insulation rating, ambient temperature correction, and conduit-fill conditions. Ventilated NEMA 1 and NEMA 2 transformers also require adequate airflow and should not be installed flush against walls or inside unventilated spaces.

4. Floor Loading. Floor loading should be reviewed before installation. A 30 kVA transformer may weigh from 150 to 480 lbs depending on configuration. Outdoor installations require NEMA 3R or another enclosure rated for the environment; standard NEMA 1 and NEMA 2 units are intended for indoor use only.

 

Why Choose Bruce Electric for 30 kVA Transformers

Bruce Electric has supplied industrial and commercial electrical distribution equipment since 1973. Our 30 kVA inventory is heavily focused on three-phase dry-type transformers, including high-demand units, The 30 kVA product data includes major manufacturers such as General Electric, HPS, Rex Power Magnetics, Acme Electric, MGM, and EGS/SolaHD and More. Inventory also includes NEMA 1, 2, 3R, encapsulated, heavy-duty, stainless steel, copper-wound, and aluminum-wound options.

Beyond standard general-purpose units, Bruce Electric can help source K-factor, harmonic mitigating, low-noise, energy-efficient, encapsulated, autotransformer, and isolation/distribution transformer types. New units are listed online, while used and reconditioned units are handled through RFQ and custom sourcing. For help selecting a 30 kVA transformer, contact Bruce Electric with your requirement.

 

Frequently Asked Questions

Q1. How many amps can a 30 kVA transformer handle?

At a 208V three-phase secondary, a 30 kVA transformer delivers approximately 83.3 amps full load. At 480V three-phase, it delivers approximately 36.1 amps. For single-phase at 240V, full-load secondary current is approximately 125 amps. Size overcurrent protection and conductors at 125% of full-load current per NEC Article 450.

Q2. What are the dimensions of a 30 kVA transformer?

A three-phase 30 kVA dry-type transformer in NEMA 2 enclosure typically measures approximately 28–38 inches high, 18–24 inches wide, and 14–20 inches deep. These are reference ranges only always confirm certified dimensions from the manufacturer datasheet before installation or conduit routing.

Q3. How much does a 30 kVA transformer weigh?

A three-phase aluminum-winding NEMA 2 unit typically weighs 250–380 lbs. Copper-winding units are heavier at approximately 300–450 lbs. NEMA 3R enclosures add additional weight. Mechanical handling equipment is required for all installations.

Q4. What is the difference between 30 kVA 480 to 208 and 208 to 480?

These are typically the same physical transformer connected in opposite orientations. In step-down use, the 480V winding is connected to the power source; in step-up use, the 208V winding connects to the source. Confirm that the specific model supports reverse-feed before step-up installation, not all winding configurations are rated for reverse-feed operation.

 